Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Find parts by applianceTrade account
Worcester Bosch Electrode Set 87181070500

Worcester Bosch

Worcester Bosch Electrode Set 87181070500

At a glance

  • Part type: Electrodes
  • Also known as WB87181070500, 1020131
  • This part is fitted to a gas appliance; installation must be carried out by a Gas Safe registered engineer.
Hanicks code
87181070500
Manufacturer part no.
87181070500
GC number
E25-323

AvailabilityCall for price

Availability: no longer made. Call us and we'll check for stock.

No longer made: call us

The manufacturer has discontinued this part. Our team will check for remaining stock or a suitable replacement.

01302 279234

Opening hours

Mon–Fri
7:30am–5pm
Sat
9am–12pm
Sun
Closed

Or request a price online

Tell us what you need and we will come back to you. No payment is taken.

Part: 87181070500 Worcester Bosch Electrode Set 87181070500

Whichever you would like us to reply to.

Helps us check the part fits.

30-day returns

Unused, in original packaging.

What it is

The Worcester Bosch 87181070500 is a set of electrodes used in the ignition and flame monitoring circuit of Worcester Bosch gas boilers. The electrodes sit in the combustion path, where they provide the ignition spark and feed the flame signal back to the control board. This set is listed for the 25 SI and 28 SI RSF combi range and the related British Gas and WR325 appliances.

Signs this part needs replacing

  • The boiler fails to light, with no spark at the burner at the start of a demand.
  • Repeated lockouts or ignition faults that clear only after a reset.
  • Intermittent flame detection, causing the burner to drop out shortly after lighting.
  • Visible damage to the electrode tips, cracked ceramic insulators or heavy sooting across the electrode assembly.
  • Erratic starting that worsens over time rather than appearing suddenly.

Before you order

  • Check the GC number or serial plate on the appliance against the compatibility list before ordering, as several SI and RSF variants use different assemblies.
  • Confirm whether the previous numbers listed below match the part currently fitted to the boiler.
  • Inspect the burner door seal and any gaskets disturbed during access, and replace them if they are compressed or perished.
  • This part is fitted to a gas appliance; installation must be carried out by a Gas Safe registered engineer.