What it is
The Nuway U90337T is an ignition electrode used on Nuway NGN series gas burners. The electrode sits at the burner head and provides the spark that lights the gas at start-up. It is listed under the supplied product name ELECTRODE.
Signs this part needs replacing
- Burner reaches lockout without lighting, with no spark at the electrode
- Spark is weak, intermittent or tracks to earth instead of the burner head
- Electrode tip is eroded, burnt back or heavily carboned
- Ceramic insulator is cracked, chipped or shows tracking marks
- Ignition becomes unreliable after the burner has been in service
Before you order
- Confirm the burner model and phase/control variant from the appliance data plate
- Check the electrode reference against the burner's own documentation before ordering
- Inspect the ignition lead and burner head for damage that may also need attention
- Confirm how many electrodes the burner head requires
Compliance
| Alternative numbers | 1451707 |
|---|
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| NUWAY NGN3 GAS BURNER | — | — | — | |
| NUWAY NGN5 GAS BURNER | — | — | — | |
| NUWAY NGN7 SINGLE PHASE HIGH/LOW | — | — | — | |
| NUWAY NGN7 SINGLE PHASE ON/OFF | — | — | — | |
| NUWAY NGN7 THREE PHASE HIGH/LOW | — | — | — | |
| NUWAY NGN7 THREE PHASE ON/OFF | — | — | — | |
| NUWAY NGN8 SINGLE PHASE HIGH/LOW | — | — | — | |
| NUWAY NGN8 SINGLE PHASE ON/OFF | — | — | — | |
| NUWAY NGN8 THREE PHASE HIGH/LOW | — | — | — | |
| NUWAY NGN8 THREE PHASE ON/OFF | — | — | — |
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
NUWAY appliance manual — NGN3 GAS BURNER, NGN5 GAS BURNER
manualmanualNUWAY appliance manual — NGN7 SINGLE PHASE HIGH/LOW, NGN7 SINGLE PHASE ON/OFF, NGN7 THREE PHASE HIGH/LOW, NGN7 THREE PHASE ON/OFF, NGN8 SINGLE PHASE HIGH/LOW, NGN8 SINGLE PHASE ON/OFF, NGN8 THREE PHASE HIGH/LOW, NGN8 THREE PHASE ON/OFF
manualNo technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.