EOGB
EOGB MMI962.1 Mod 23 Control Box
EOGB MMI962.1 Mod 23 control box for Honeywell Satronic burner control applications.
£707.92
£589.93 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The MMI962.1 Mod 23 Control box is an EOGB burner control box used on Honeywell Satronic control platforms. It manages the burner sequence, including start-up, flame supervision and lockout, on the appliances it is fitted to.
Signs this part needs replacing
- The burner runs through the pre-purge but fails to reach flame and locks out.
- The control box locks out repeatedly with no ignition attempt at the electrode.
- Reset is required on every start cycle, or the lockout lamp stays on.
- The burner sequence stalls partway through start-up and does not complete.
- Intermittent lockouts that clear on reset but return after a short run.
Before you order
- Confirm the existing control box is marked MMI962.1 Mod 23, as other variants in the range are not interchangeable.
- Check the appliance is an EOGB unit running a Honeywell Satronic control platform.
- Note the wiring connections and plug orientation before removing the old control box.
- Ensure the fault is traced to the control box rather than the flame sensor, ignition electrode or gas supply.
No specification data held for this part.
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| EOGB Honeywell - Satronic | — | — | — |
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
No documents held for this part. The technical team will source them from the manufacturer — usually the same working day.
No technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.