EOGB Detector L01-QRB1A-B036A25A

EOGB

EOGB Detector L01-QRB1A-B036A25A

Detector for EOGB Siemens and Landis boiler control systems, part L01-QRB1A-B036A25A.

Manufacturer part no.
L01-QRB1A-B036A25A
Showing prices

£65.20

£54.33 ex. VAT · VAT at 20%

Available to order · 3 working days
Available to order · 3 working days
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Detector is an EOGB component intended for use with Siemens and Landis boiler control systems. It forms part of the boiler's flame monitoring circuit, signalling to the control board whether a flame is present at the burner. It is supplied under part number L01-QRB1A-B036A25A.

Signs this part needs replacing

  • Boiler locks out repeatedly during or shortly after ignition.
  • Burner fails to establish a flame signal and the control shuts the appliance down.
  • Intermittent lockouts or nuisance shutdowns with no other fault indicated.
  • Boiler fires briefly then trips on flame loss.

Before you order

  • Confirm the boiler's control unit is a Siemens or Landis type as listed.
  • Check the existing detector's part number against L01-QRB1A-B036A25A.
  • Inspect the detector lead and connector for damage before concluding the detector itself has failed.