EOGB
EOGB Danfoss 057H7109 LDS Photocell
LDS photocell for EOGB Danfoss boilers, supplied with a 600mm hose.
At a glance
- Also known as 2090015
£40.32
£33.60 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The EOGB Danfoss 057H7109 is an LDS photocell used on EOGB Danfoss boiler appliances. It monitors the flame within the combustion chamber and provides the flame signal to the burner control, allowing the boiler to prove ignition and shut down safely if the flame is lost. This is the high-sensitivity variant, supplied with a 600mm hose.
Signs this part needs replacing
- Burner locks out shortly after ignition despite a visible flame
- Repeated lockouts that clear on reset but return on the next cycle
- Flame signal is weak or intermittent when measured at the control
- Boiler fails to prove flame and shuts down during the lighting sequence
- Photocell window is discoloured, sooted or clouded and cleaning does not restore reliable operation
Before you order
- Confirm the appliance is an EOGB Danfoss unit and that the existing photocell carries the 057H7109 reference
- Check the lead length and hose routing match the 600mm assembly on the appliance
- Inspect the photocell holder and window for sooting or damage before fitting a new unit
- Verify the burner control and ignition components are sound, so a lockout is not being caused elsewhere
Compliance
| Alternative numbers | 2090015 |
|---|
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| EOGB Danfoss | — | — | — |
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
No documents held for this part. The technical team will source them from the manufacturer — usually the same working day.
No technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.