Andrews
Andrews Thermocouple C132AWH
Thermocouple C132AWH for Andrews water heaters and boilers, used to sense the pilot flame and maintain gas valve operation.
At a glance
- Also known as 1820040
£37.13
£30.94 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
This thermocouple is a flame-sensing safety component for Andrews water heaters and boilers. It generates a small voltage when heated by the pilot flame, allowing the gas valve to remain open while a flame is proven. The part is identified by Andrews part number C132AWH and is listed as a standard thermocouple.
Signs this part needs replacing
- Pilot flame goes out when the gas control knob is released.
- Appliance fails to stay lit after the pilot flame is established.
- Repeated flame failure lockouts during operation.
- Burner does not remain alight, so hot water is not produced.
- Pilot flame will not hold or appears unstable.
Before you order
- Confirm the appliance model is listed in the Fits section.
- Check the existing thermocouple is marked C132AWH or the appliance documentation specifies this part number.
- Inspect the pilot assembly and gas valve for other faults before replacing the thermocouple.
- Check the connection type and lead length against the removed component.
Compliance
| Barcode / EAN | 5039177515388 |
|---|---|
| Alternative numbers | 1820040 |
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| ANDREWS WATER HEATERS 84/87 STANDARD | — | — | — | |
| ANDREWS WATER HEATERS ANDREWS HOT WATER SPARES | — | — | — | |
| ANDREWS WATER HEATERS RSC 150 | — | — | — | |
| ANDREWS WATER HEATERS RSC 190 | — | — | — |