Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Worcester Bosch Gas Conversion Kit 87190010670

Worcester Bosch

Worcester Bosch Gas Conversion Kit 87190010670

Gas conversion kit for Worcester Bosch Greenstar 30CDI appliances, converting LPG operation to natural gas.

At a glance

  • Appliance family: Worcester Greenstar 30CDI Conventional and 30CDI ErP Classic Regular
  • Also known as 1020185
  • Conversion must be carried out by a Gas Safe registered engineer.
Manufacturer part no.
87190010670
GC number
H31-873
Showing prices

£11.21

£9.34 ex. VAT · VAT at 20%

Available to order · 3 working days
Available to order · 3 working days
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

This is a gas conversion kit manufactured by Worcester Bosch, part number 87190010670. It is used to convert a Worcester Greenstar 30CDI appliance from LPG operation to natural gas operation. The kit is specific to the 30CDI Conventional and 30CDI ErP Classic Regular models listed below.

Signs this part needs replacing

  • The appliance is configured for LPG but the property is supplied with natural gas.
  • The boiler will not ignite correctly or burns incorrectly because the gas type does not match the appliance setting.
  • A conversion is required following a change in the gas supply to the property.
  • The existing conversion kit is missing, incomplete or has been removed from the appliance.
  • Gas type labelling or injector configuration on the appliance does not match the fuel being supplied.

Before you order

  • Confirm your appliance model and GC number against the fit list above.
  • Confirm the appliance is currently set for LPG and that the supply to be used is natural gas.
  • Check the appliance data badge for the model and gas category before ordering.
  • Conversion must be carried out by a Gas Safe registered engineer.

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.