Vokera
Vokera Pressure Tube Negative Venturi 7948
Negative venturi pressure tube, part 7948, for Vokera gas boilers built before May 2006.
At a glance
- Part type: negative venturi pressure tube
- Also known as VENTURI-REP-6984-NEGATIVE, 1531324
£14.78
£12.32 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The negative venturi pressure tube is a Vokera gas boiler component used within the appliance's air and gas circuit. It forms part of the pressure sensing arrangement on pre-May 2006 Vokera boiler platforms, including the Excell, Linea, Maxin and Mynute ranges. The part carries the manufacturer reference 7948.
Signs this part needs replacing
- The boiler fails to ignite or drops into lockout without an obvious cause elsewhere
- Combustion readings drift or the gas and air mixture cannot be set correctly
- The flame is unstable, noisy or lifts away from the burner
- Whistling or unusual noise from the air and gas circuit
- Visible damage, blockage or splitting on the tube itself
Before you order
- Confirm the boiler model against the fitment list above
- Check whether the appliance uses new or old hydraulics where the model is listed in both variants
- Check the serial number on Linea Mk1 and Mk2 models, as the changeover point affects fitment
- Confirm the appliance was built before May 2006
Compliance
| GC number | E01-785 |
|---|---|
| Alternative numbers | VENTURI-REP-6984-NEGATIVE, 1531324 |
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| VOKERA AQUANOVA | 52-094-03 | 52-094-03 | — | — |
| VOKERA EXCELL 80E (NEW HYDRAULICS) | 47-094-18 | 47-094-18 | — | — |
| VOKERA EXCELL 80SP (NEW HYDRAULICS) | 47-094-17 | 47-094-17 | — | — |
| VOKERA EXCELL 80SP (OLD HYDRAULICS) | 47-094-16 | 47-094-16 | — | — |
| VOKERA EXCELL 96E (NEW HYDRAULICS) | 47-094-19 | 47-094-19 | — | — |
| VOKERA LINEA 24 MK1 - UP TO 161380001 | 47-094-27 | 47-094-27 | — | — |
| VOKERA LINEA 24 MK2 - AFTER 161380001 | 47-094-27 | 47-094-27 | — | — |
| VOKERA LINEA 28 MK1 - UP TO 164370001 | 47-094-28 | 47-094-28 | — | — |
| VOKERA LINEA 28 MK2 - AFTER 164370001 | 47-094-28 | 47-094-28 | — | — |
| VOKERA LINEA MAX SE | 47-094-30 | 47-094-30 | — | — |
Showing 10 of 48 compatible appliances.
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
VOKERA appliance manual — AQUANOVA (GC 52-094-03)
manualmanualVOKERA appliance manual — EXCELL 80E (NEW HYDRAULICS) (GC 47-094-18), EXCELL 96E (NEW HYDRAULICS) (GC 47-094-19)
manualmanualVOKERA appliance manual — EXCELL 80SP (NEW HYDRAULICS) (GC 47-094-17), EXCELL 80SP (OLD HYDRAULICS) (GC 47-094-16)
manualmanualVOKERA appliance manual — LINEA 24 MK1 - UP TO 161380001 (GC 47-094-27), LINEA 24 MK2 - AFTER 161380001 (GC 47-094-27), LINEA 28 MK1 - UP TO 164370001 (GC 47-094-28), LINEA 28 MK2 - AFTER 164370001 (GC 47-094-28)
manualmanualVOKERA appliance manual — LINEA MAX SE (GC 47-094-30)
manualmanualVOKERA appliance manual — LINEA PLUS AG (GC 47-094-31)
manualmanualVOKERA appliance manual — MAXIN 24E (GC 47-094-22), MAXIN 28E (GC 47-094-23)
manualmanualVOKERA appliance manual — MYNUTE 10 SE (GC 41-094-11), MYNUTE 14 SE (GC 41-094-12), MYNUTE 20 SE (GC 41-094-13)
manualmanualVOKERA appliance manual — MYNUTE 10e (GC 41-094-15), MYNUTE 14e (GC 41-094-16), MYNUTE 20e (EARLY MODELS) (GC 41-094-17), MYNUTE 20e (LATER MODELS) (GC 41-094-17)
manualmanualVOKERA appliance manual — MYNUTE 12e (GC 41-094-21), MYNUTE 16e (GC 41-094-22)
manualmanualVOKERA appliance manual — MYNUTE 14/48 SE (GC 41-094-06), MYNUTE 20/70 SE (GC 41-094-07)
manualmanualVOKERA appliance manual — MYNUTE 14/48 SP (GC 41-094-09)
manualmanualVOKERA appliance manual — MYNUTE 28/96SE (GC 41-094-08)
manualmanualVOKERA appliance manual — MYNUTE 28SE (GC 41-094-14)
manualNo technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.