Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Andrews Pipe Flow Sensor Valve to Secondary Heat Exchanger 7702405

Andrews

Andrews Pipe Flow Sensor Valve to Secondary Heat Exchanger 7702405

Pipe assembly connecting the flow sensor to the secondary heat exchanger on Andrews Fastflo water heaters.

At a glance

  • Also known as 1822998
Manufacturer part no.
7702405
Showing prices

£72.94

£60.78 ex. VAT · VAT at 20%

Available to order · 3 working days
Available to order · 3 working days
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Andrews 7702405 is a pipe that links the flow sensor to the secondary heat exchanger on Andrews water heaters. It forms part of the water circuit on the Fastflo range, carrying flow between the sensor and the heat exchanger. The pipe is supplied as a single component for service and repair work.

Signs this part needs replacing

  • Water weeping or dripping from the pipe or its connections
  • Visible corrosion, pitting or scale build-up on the pipework
  • Reduced hot water flow or inconsistent outlet temperature
  • Repeated flow sensor faults or lockouts traced to the pipe

Before you order

  • Confirm the appliance model against the fit list above
  • Check that part number 7702405 matches the component being replaced
  • Inspect the flow sensor and secondary heat exchanger connections for damage before fitting

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.