Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Alpha Programmable Room Thermostat Easy-Stat RF 7.2000050

Alpha

Alpha Programmable Room Thermostat Easy-Stat RF 7.2000050

At a glance

  • Part type: Clocks and timers
  • Also known as 1250858
  • This part is fitted to a gas appliance; installation must be carried out by a Gas Safe registered engineer.
Manufacturer part no.
7.2000050
Showing prices

£101.34

£84.45 ex. VAT · VAT at 20%

In stock
Order within 8m for same-day dispatch
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Alpha Easy-Stat is a programmable room thermostat supplied by Alpha for use with its CD28C Extra, HE25 and HE33 boiler ranges. It works alongside a receiver that is installed inside the boiler control panel, and the two communicate over an 868 MHz radio frequency link. The thermostat sets the room temperature and the heating schedule, and passes demand to the boiler through the receiver.

Signs this part needs replacing

  • The boiler no longer responds to calls for heat from the thermostat
  • The thermostat loses its RF link with the receiver in the boiler control panel
  • The display goes blank, dims or shows incomplete segments
  • Room temperature readings drift noticeably from the actual room temperature
  • Schedule or setpoint changes are not held

Before you order

  • Check the GC number on the appliance data badge against the compatibility list.
  • Confirm the existing part number; earlier numbers 6.1000210 and 6.1000250 are listed for this application.
  • The receiver is installed into the boiler control panel, so refer to the boiler installation manual for guidance.
  • The thermostat must be sited approximately 1.5 m from the ground, away from direct sunlight, heat sources, draughts, curtains and furniture.
  • This part is fitted to a gas appliance; installation must be carried out by a Gas Safe registered engineer.

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.