Ecoflam
Ecoflam Ionisation Probe 65320892
Ionisation probe for Ecoflam BLU PR series boilers, part number 65320892.
£44.99
£37.49 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The ionisation probe (flame sensing electrode) for Ecoflam BLU PR series boilers, supplied under part number 65320892. It sits in the burner flame path and provides the flame supervision signal to the control box, which proves the burner has lit and allows it to run. The listed reference for this probe is D10X100 D6 4 D3X70 90.
Signs this part needs replacing
- Burner locks out shortly after ignition or fails to prove flame
- Repeated lockouts on start-up with the gas and ignition circuits otherwise sound
- Probe tip heavily sooted, oxidised or eroded
- Cracked or discoloured ceramic insulator, or a contaminated electrode
Before you order
- Confirm the boiler model against the fit list above, as fitment varies across the BLU range
- Check the existing probe part number and electrode dimensions before ordering
- Inspect the electrode lead and control box earth path, since a poor connection can mimic probe failure
- Handle the ceramic insulator carefully on fitting to avoid cracking it
No specification data held for this part.
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| ECOFLAM BLU 3000.1 CODE PR/MD | — | — | — | |
| ECOFLAM BLU 4000.1 CODE PR/MD | — | — | — | |
| ECOFLAM BLU 5000.1 PR / MD | — | — | — | |
| ECOFLAM BLU 6000.1 PR / MD | — | — | — | |
| ECOFLAM BLU TS 2000.1 PR | — | — | — | |
| ECOFLAM SPARES ECOFLAM PRODUCTS | — | — | — |
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
No technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.