Chaffoteaux
Chaffoteaux Pressure Sensor 0.8 B 61003495
Pressure sensor rated 0.8 B for Chaffoteaux Britony Combi SE, Moduloflame 140, Elexia Comfort and MC 2 boilers.
At a glance
- Also known as PRESSURE-SENSOR-08-B
£68.76
£57.30 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The Chaffoteaux 61003495 is a pressure sensor rated 0.8 B, used across a number of Chaffoteaux combi and wall-mounted gas boilers. It reads system pressure and passes that signal to the appliance control board, and is also listed as a pressure switch/detector for the Moduloflame 140 range. It is a service component for the Britony Combi SE, Elexia Comfort, MC 2 and Moduloflame families.
Signs this part needs replacing
- Boiler locks out or reports a low-pressure fault when the system pressure is correct
- Pressure gauge reading does not match the boiler's behaviour or firing pattern
- Repeated low-pressure or ignition lockout errors after refilling and venting the system
- Boiler fails to fire, or modulates erratically as pressure changes
- Visible corrosion, cracking or leakage at the sensor body or its connection
Before you order
- Confirm your appliance model and variant against the fit list above
- Check the rating marked on the existing sensor matches 0.8 B
- Inspect the wiring connector and any sealing washer for damage before refitting
- Isolate and depressurise the appliance before removing the sensor
Compliance
| Alternative numbers | PRESSURE-SENSOR-08-B |
|---|
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| CHAFFOTEAUX BRITONY COMBI SE 100 LPG - FROM AUG 2001 | 47-980-19 | 47-980-19 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 100 LPG - OCT 2007 | 47-980-19 | 47-980-19 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 100 NAT GAS - FROM MAR 2001 | 47-980-17 | 47-980-17 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 100 NAT GAS - OCT 2007 | 47-980-17 | 47-980-17 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 80 LPG - FROM APR 2001 | 47-980-18 | 47-980-18 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 80 LPG - OCT 2007 | 47-980-18 | 47-980-18 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 80 NAT GAS - FROM FEB 2001 | 47-980-16 | 47-980-16 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 80 NAT GAS - OCT 2007 | 47-980-16 | 47-980-16 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 80 TIMER LPG - FROM APR 2001 | 47-980-18 | 47-980-18 | — | — |
| CHAFFOTEAUX BRITONY COMBI SE 80 TIMER LPG - OCT 2007 | 47-980-18 | 47-980-18 | — | — |
Showing 10 of 20 compatible appliances.
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
CHAFFOTEAUX appliance manual — BRITONY COMBI SE 100 LPG - FROM AUG 2001 (GC 47-980-19), BRITONY COMBI SE 100 LPG - OCT 2007 (GC 47-980-19), BRITONY COMBI SE 100 NAT GAS - FROM MAR 2001 (GC 47-980-17), BRITONY COMBI SE 100 NAT GAS - OCT 2007 (GC 47-980-17), BRITONY COMBI SE 80 LPG - FROM APR 2001 (GC 47-980-18), BRITONY COMBI SE 80 LPG - OCT 2007 (GC 47-980-18), BRITONY COMBI SE 80 NAT GAS - FROM FEB 2001 (GC 47-980-16), BRITONY COMBI SE 80 NAT GAS - OCT 2007 (GC 47-980-16), BRITONY COMBI SE 80 TIMER LPG - FROM APR 2001 (GC 47-980-18), BRITONY COMBI SE 80 TIMER LPG - OCT 2007 (GC 47-980-18), BRITONY COMBI SE 80 TIMER NAT GAS - FROM FEB 2001 (GC 47-980-16), BRITONY COMBI SE 80 TIMER NAT GAS - OCT 2007 (GC 47-980-16)
manualmanualCHAFFOTEAUX appliance manual — MODULOFLAME 140 NAT GAS GB
manualNo technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.