Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Ariston Circulation Pump 5m PWM 60001947-02

Ariston

Ariston Circulation Pump 5m PWM 60001947-02

Ariston 60001947-02 circulation pump with 5 m head and PWM speed control, for CLAS PREMIUM EVO and CLAS PREMIUM EVO SYSTEM boilers.

At a glance

  • Part type: circulation pump
  • Appliance family: CLAS PREMIUM EVO, CLAS PREMIUM EVO SYSTEM
  • Also known as 1580009
Manufacturer part no.
60001947-02
Showing prices

£292.74

£243.95 ex. VAT · VAT at 20%

In stock
Order within 2m for same-day dispatch
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Ariston 60001947-02 is a circulation pump (Pumpenzirkulator) rated at a 5 m head with PWM speed control. It is the pump that moves water around the heating circuit of the appliance, and its PWM connection lets the boiler control board vary pump speed to match demand rather than running at a fixed rate.

It is supplied as a spare for Ariston CLAS PREMIUM EVO and CLAS PREMIUM EVO SYSTEM wall-mounted boilers. The part is listed under the manufacturer code 60001947-02 and replaces earlier numbers 60001947 and 60001947-01.

Signs this part needs replacing

  • No heating or no hot water because the pump is not turning
  • Pump runs but the boiler reports a circulation or flow fault
  • Radiators stay cold or heat unevenly while the boiler fires
  • Grinding, humming or rattling noise from the pump body
  • Pump speed does not change with demand, pointing to a failed PWM signal or seized rotor

Before you order

  • Confirm your boiler model and serial number against the compatibility list, as the pump is specific to the CLAS PREMIUM EVO range
  • Check the number on the pump you are removing: earlier versions carry 60001947 or 60001947-01
  • Inspect the pump gasket and sealing faces before refitting and renew them if they are compressed or damaged
  • Isolate the electrical supply and drain or isolate the water circuit before removing the old pump

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.