Baxi
Baxi NTC Return Sensor Clip 5114726
Baxi 5114726 NTC return sensor clip, a thermistor-type sensor for Baxi Megaflo systems.
At a glance
- Part type: Sensor (NTC thermistor)
£20.40
£17.00 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The Baxi 5114726 NTC return sensor clip is a sensor in the Baxi sensors range, classed as a thermistor. It is an NTC (negative temperature coefficient) sensor that clips onto the return pipe of the heating circuit, where it measures the temperature of the water returning to the boiler. It is used in Baxi Megaflo system boilers.
Before you order
- Check your boiler's model name, GC number and serial number against the fitment list above, as several Megaflo variants are listed by serial number range.
- Confirm the sensor type you are replacing is a return sensor and that it clips onto the return pipe.
- Use the GC number on the appliance data badge to match the correct variant where one is listed.
Compliance
| GC number | H29-108 |
|---|
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| BAXI MEGAFLO 15 HE A SYSTEM | 41-075-55 | 41-075-55 | — | — |
| BAXI MEGAFLO 15 HE SYSTEM | 41-075-52 | 41-075-52 | — | — |
| BAXI MEGAFLO 15 SYSTEM IE ErP SERIAL No. ENDING AC | — | — | — | |
| BAXI MEGAFLO 15 SYSTEM IE ErP SERIAL No. ENDING BC | — | — | — | |
| BAXI MEGAFLO 15 SYSTEM IE ErP SERIAL No. ENDING CC | — | — | — | |
| BAXI MEGAFLO 18 HE A SYSTEM | 41-075-56 | 41-075-56 | — | — |
| BAXI MEGAFLO 18 HE A SYSTEM LPG | 41-075-61 | 41-075-61 | — | — |
| BAXI MEGAFLO 18 HE SYSTEM | 41-075-53 | 41-075-53 | — | — |
| BAXI MEGAFLO 18 SYSTEM IE ErP SERIAL No. ENDING AC | — | — | — | |
| BAXI MEGAFLO 18 SYSTEM IE ErP SERIAL No. ENDING BC | — | — | — |
Showing 10 of 84 compatible appliances.
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
BAXI appliance manual — MEGAFLO 15 HE A SYSTEM (GC 41-075-55), MEGAFLO 18 HE A SYSTEM (GC 41-075-56), MEGAFLO 24 HE A SYSTEM BEFORE BTF 0932 (GC 41-075-57), MEGAFLO 24 HE A SYSTEM FROM SERIAL NO BTF 0932 (GC 41-075-57), MEGAFLO 28 HE A SYSTEM BEFORE CAB 1112 (GC 41-075-58), MEGAFLO 28 HE A SYSTEM FROM SERIAL NO CAB 1112 (GC 41-075-58), MEGAFLO 32 HE A SYSTEM (GC 41-075-59)
manualmanualBAXI appliance manual — MEGAFLO 15 HE SYSTEM (GC 41-075-52), MEGAFLO 18 HE SYSTEM (GC 41-075-53), MEGAFLO 24 HE SYSTEM (GC 41-075-47), MEGAFLO 28 HE SYSTEM (GC 41-075-57)
manualmanualBAXI appliance manual — MEGAFLO 18 HE A SYSTEM LPG (GC 41-075-61), MEGAFLO 28 HE A SYSTEM LPG BEFORE SERIAL No. FSR 1112 (GC 41-075-62), MEGAFLO 28 HE A SYSTEM LPG FROM SERIAL No. FSR 1112 (GC 41-075-62), MEGAFLO 32 HE A SYSTEM LPG (GC 41-075-59)
manualmanualBAXI appliance manual — MEGAFLO SYSTEM ErP 15 SERIAL No. ENDING AC (GC 41-470-18), MEGAFLO SYSTEM ErP 15 SERIAL No. ENDING BC (GC 41-470-18), MEGAFLO SYSTEM ErP 15 SERIAL No. ENDING CC (GC 41-470-18), MEGAFLO SYSTEM ErP 18 SERIAL No. ENDING AC (GC 41-470-19), MEGAFLO SYSTEM ErP 18 SERIAL No. ENDING BC (GC 41-470-19), MEGAFLO SYSTEM ErP 18 SERIAL No. ENDING CC (GC 41-470-19), MEGAFLO SYSTEM ErP 24 SERIAL No. ENDING AC (GC 41-470-20), MEGAFLO SYSTEM ErP 24 SERIAL No. ENDING BC (GC 41-470-20), MEGAFLO SYSTEM ErP 24 SERIAL No. ENDING CC (GC 41-470-20), MEGAFLO SYSTEM ErP 28 SERIAL No. ENDING AC (GC 41-470-21), MEGAFLO SYSTEM ErP 28 SERIAL No. ENDING BC (GC 41-470-21), MEGAFLO SYSTEM ErP 28 SERIAL No. ENDING CC (GC 41-470-21), MEGAFLO SYSTEM ErP 32 SERIAL No. ENDING AC (GC 41-470-22), MEGAFLO SYSTEM ErP 32 SERIAL No. ENDING BC (GC 41-470-22), MEGAFLO SYSTEM ErP 32 SERIAL No. ENDING CC (GC 41-470-22)
manualmanualPOTTERTON appliance manual — GOLD SYSTEM ErP 18 SERIAL No. ENDING AC (GC 41-592-39), GOLD SYSTEM ErP 18 SERIAL No. ENDING BC & CC (GC 41-592-39), GOLD SYSTEM ErP 18 SERIAL No. ENDING DC (GC 41-592-39), GOLD SYSTEM ErP 24 SERIAL No. ENDING AC (GC 41-592-40), GOLD SYSTEM ErP 24 SERIAL No. ENDING BC & CC (GC 41-592-40), GOLD SYSTEM ErP 24 SERIAL No. ENDING DC (GC 41-592-40), GOLD SYSTEM ErP 28 SERIAL No. ENDING AC (GC 41-592-41), GOLD SYSTEM ErP 28 SERIAL No. ENDING BC & CC (GC 41-592-41), GOLD SYSTEM ErP 28 SERIAL No. ENDING DC (GC 41-592-41)
manualmanualPOTTERTON appliance manual — GOLD SYSTEM HE A 28 - AFTER SERIAL No. HSA 1112 (GC 41-592-17), GOLD SYSTEM HE A 28 - BEFORE SERIAL No. HSA 1112 (GC 41-592-17)
manualmanualPOTTERTON appliance manual — PROMAX PLUS A SYSTEM 12 HE (GC 41-591-99), PROMAX PLUS A SYSTEM 15 HE (GC 41-592-01), PROMAX PLUS A SYSTEM 18 HE (GC 41-592-02), PROMAX PLUS A SYSTEM 24 HE (AFTER SERIAL NO. AWD 0932) (GC 41-592-03), PROMAX PLUS A SYSTEM 24 HE (BEFORE SERIAL NO. AWD 0932) (GC 41-592-03), PROMAX PLUS A SYSTEM 32 HE (GC 41-592-04)
manualmanualPOTTERTON appliance manual — PROMAX PLUS SYSTEM 12 HE (GC 41-591-90), PROMAX PLUS SYSTEM 15 HE (GC 41-591-91), PROMAX PLUS SYSTEM 18 HE (GC 41-591-92), PROMAX PLUS SYSTEM 24 HE (GC 41-601-21), PROMAX PLUS SYSTEM 32 HE (GC 41-591-93)
manualmanualPOTTERTON appliance manual — PROMAX PLUS SYSTEM 24 HE LPG (AFTER SERIAL NO. ELW 0932) (GC 41-592-11), PROMAX PLUS SYSTEM 24 HE LPG (BEFORE SERIAL NO. ELW 0932) (GC 41-592-11)
manualmanualPOTTERTON appliance manual — PROMAX SYSTEM Erp 12 - SERIAL No. ENDING AC (GC 41-592-42), PROMAX SYSTEM Erp 12 - SERIAL No. ENDING BC & CC (GC 41-592-42), PROMAX SYSTEM Erp 12 - SERIAL No. ENDING DC (GC 41-592-42), PROMAX SYSTEM Erp 15 - SERIAL No. ENDING AC (GC 41-592-43), PROMAX SYSTEM Erp 15 - SERIAL No. ENDING BC & CC (GC 41-592-43), PROMAX SYSTEM Erp 15 - SERIAL No. ENDING DC (GC 41-592-43), PROMAX SYSTEM Erp 18 - SERIAL No. ENDING AC (GC 41-592-44), PROMAX SYSTEM Erp 18 - SERIAL No. ENDING BC & CC (GC 41-592-44), PROMAX SYSTEM Erp 18 - SERIAL No. ENDING DC (GC 41-592-44), PROMAX SYSTEM Erp 24 - SERIAL No. ENDING AC (GC 41-592-45), PROMAX SYSTEM Erp 24 - SERIAL No. ENDING BC & CC (GC 41-592-45), PROMAX SYSTEM Erp 24 - SERIAL No. ENDING DC (GC 41-592-45), PROMAX SYSTEM Erp 32 - SERIAL No. ENDING AC (GC 41-592-46), PROMAX SYSTEM Erp 32 - SERIAL No. ENDING BC & CC (GC 41-592-46), PROMAX SYSTEM Erp 32 - SERIAL No. ENDING DC (GC 41-592-46)
manualNo technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.