Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Myson Thermocouple C/W Nuts 308S048

Myson

Myson Thermocouple C/W Nuts 308S048

At a glance

  • Part type: Thermocouple
  • Also known as 1180022
  • This part is fitted to a gas appliance; installation must be carried out by a Gas Safe registered engineer.
Manufacturer part no.
308S048
GC number
384-971
Showing prices

£10.28

£8.57 ex. VAT · VAT at 20%

In stock
Cut-off passed — dispatches next working day
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Myson 308S048 is a thermocouple supplied complete with nuts. It is a flame-sensing safety device used in Myson Housewarmer back boiler unit gas fires, where it holds the gas valve open only while the pilot flame is proven. If the pilot flame is lost, the thermocouple output collapses and the valve closes, shutting off the gas supply to the burner.

Signs this part needs replacing

  • The pilot flame lights but goes out as soon as the control knob is released.
  • The appliance repeatedly locks out or shuts down shortly after the burner has been lit.
  • The pilot flame is established but the gas valve will not hold in.
  • The pilot flame appears weak or unstable at the thermocouple tip.
  • The thermocouple lead or tip shows heat damage, corrosion or a loose connection at the valve.

Before you order

  • Check the appliance GC number against the compatibility list to confirm the correct thermocouple for your Housewarmer model.
  • Confirm the model and variant of your Housewarmer BBU fire, as several fire fronts share the 30/45 BBU and 45 BBU chassis.
  • This part is fitted to a gas appliance; installation must be carried out by a Gas Safe registered engineer.

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.