Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Vaillant Impeller Cpl. Aqua Sensor 194829

Vaillant

Vaillant Impeller Cpl. Aqua Sensor 194829

Vaillant impeller assembly with integrated aqua sensor for Ecomax 2E and VUW 246/2 series gas boilers.

At a glance

  • Also known as 1374113
Manufacturer part no.
194829
Showing prices

£107.14

£89.28 ex. VAT · VAT at 20%

Available to order · 3 working days
Available to order · 3 working days
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Vaillant 194829 impeller, complete with aqua sensor, is a hydraulic sensing component used in the domestic hot water circuit of Vaillant gas boilers. The impeller rotates with water flow through the DHW section, and the aqua sensor registers that movement so the boiler can recognise a hot water draw-off. It is listed under switches within the gas boiler spares range.

Signs this part needs replacing

  • The boiler does not fire when a hot water tap is opened, despite the tap running freely.
  • Hot water demand is recognised intermittently, giving inconsistent or delayed DHW operation.
  • The impeller is stiff, seized or visibly damaged when the housing is inspected.
  • Scale, sludge or debris has built up around the impeller, preventing free rotation.
  • DHW faults persist after the flow rate and inlet filters have been checked.

Before you order

  • Confirm the boiler model and GC number against the fitment list above.
  • Check the part number marked on the existing impeller or sensor housing.
  • Verify whether the boiler is the Ecomax 2E or Ecomax 824/2 E-C variant, as both use this assembly.
  • Inspect the surrounding hydraulic housing for damage or debris before fitting.

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.