Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Ideal Flue Gasket Double Lip Seal 100mm 177490

Ideal

Ideal Flue Gasket Double Lip Seal 100mm 177490

Ideal 177490 flue gasket with a double lip seal and 100 mm diameter, for Evomax commercial boilers and other Ideal appliances.

At a glance

  • Part type: Gaskets, o-rings, seals and washers
  • This part is fitted to a gas appliance; installation must be carried out by a Gas Safe registered engineer.
Manufacturer part no.
177490
Showing prices

£10.82

£9.02 ex. VAT · VAT at 20%

Available to order · 3 working days
Available to order · 3 working days
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Ideal 177490 is a flue gasket with a double lip seal, sized at 100 mm diameter. It seats at the flue connection on the appliance, where the twin sealing lips close against the mating surface to hold the joint gas-tight and stop flue products escaping into the room. It is supplied as an Ideal Spares component for the Evomax commercial range and other Ideal appliances listed in the compatibility data.

Signs this part needs replacing

  • Flue gas smell or combustion readings drifting at the flue joint on the appliance
  • Visible cracking, hardening or flattening of the sealing lips
  • Condensate staining, rust marks or water tracking around the flue connection
  • Soot deposits or discolouration at the joint face
  • The gasket lifting or sitting proud when the flue is refitted after servicing

Before you order

  • Confirm the appliance model and GC number against the compatibility list, as the same flue gasket is not used across every Ideal appliance.
  • Check the flue spigot diameter measures 100 mm before fitting, since the seal is sized to that connection.
  • If the flue joint is being disturbed as part of a service or flue replacement, check whether any other seals in the assembly also need renewing.
  • This part is fitted to a gas appliance; installation must be carried out by a Gas Safe registered engineer.

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.