Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Ideal Hydroblock Assembly Complete 32kW 176878

Ideal

Ideal Hydroblock Assembly Complete 32kW 176878

Ideal 176878 hydroblock complete, a 32kW diverter and hydraulics assembly for Ideal Vogue C32 boilers, GC 47-348-98.

At a glance

  • Part type: Hydroblock / diverter valves and hydraulics
  • Also known as 1782723
Manufacturer part no.
176878
Showing prices

£1,091.71

£909.76 ex. VAT · VAT at 20%

Available to order · 3 working days
Available to order · 3 working days
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Ideal 176878 is a complete hydroblock assembly rated at 32kW, listed by the manufacturer under diverter valves and hydraulics. It forms the water-side core of the boiler, carrying the diverter section that switches flow between domestic hot water and central heating, along with the associated hydraulic components in a single factory-built unit. It is used across the Ideal Vogue C32 range and appears in Ideal Commercial parts listings.

Signs this part needs replacing

  • Domestic hot water runs cold or only warms intermittently while the heating circuit works normally
  • Radiators heat up when only hot water is demanded, indicating the diverter section is passing
  • Water weeping or staining around the hydroblock body, unions or the diverter housing
  • Boiler pressure dropping repeatedly with no visible leak elsewhere on the system
  • Fault codes or lockouts linked to diverter or hydraulic operation on the appliance display

Before you order

  • Confirm the appliance model and GC number against the compatibility list, as the 32kW hydroblock is specific to this rating
  • Check the existing part number on the boiler against 176878 and the alternative number 1782723 before ordering
  • Inspect the unions, seals and washers on removal and renew them as needed to avoid leaks on reassembly
  • Work on the boiler should be carried out by a competent person, with the appliance isolated and drained as required

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.