What it is

The Ideal 32kW flow turbine (part 176875) is a flow switch component used inside Ideal domestic and commercial appliances. It sits in the water circuit and responds to the movement of water through the unit, signalling the appliance when a draw-off takes place so that the relevant sequence of operation can begin. It is listed by Ideal under the flow regulators and governors spare part group.

Signs this part needs replacing

  • The appliance fails to respond when a hot water outlet is opened.
  • Domestic hot water runs intermittently or cuts out during a draw-off.
  • The boiler does not fire on a hot water demand even though the tap is running.
  • Fault codes or lockouts relating to water flow appear on the appliance display.
  • The turbine or its housing shows scale, debris or mechanical wear when inspected.

Before you order

  • Check the GC number on the appliance data badge against 47-348-98 to confirm the model.
  • Confirm the part number 176875 or the alternative number 1782627 matches the component being replaced.
  • Inspect the surrounding seals and connections while the appliance is open, and renew any that show signs of hardening or leakage.

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.