Vaillant Temperature Limiter 101384

Vaillant

Vaillant Temperature Limiter 101384

Vaillant temperature limiter, part number 101384, for Thermocompact fanned flue gas boilers.

At a glance

  • Part type: temperature limiter
  • Appliance family: Thermocompact fanned flue
  • Also known as 1373420
Manufacturer part no.
101384
GC number
264-203
Showing prices

£44.09

£36.74 ex. VAT · VAT at 20%

Available to order · 3 working days
Available to order · 3 working days
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Vaillant 101384 is a temperature limiter used in Vaillant Thermocompact fanned flue gas boilers. It forms part of the boiler's temperature control and safety circuit, cutting the appliance out if the sensed temperature exceeds its set limit. It is listed under thermostats within gas boiler spares.

Signs this part needs replacing

  • The boiler locks out or shuts down before reaching its normal operating temperature.
  • The appliance will not fire, or fires only briefly before cutting out.
  • Repeated resetting is needed to keep the boiler running.
  • The limiter shows signs of heat damage, scorching or a loose or corroded connection.
  • Fault codes or lockout behaviour consistent with an overheat trip.

Before you order

  • Confirm the boiler model against the fitment list above.
  • Check the existing limiter's part number and connections match 101384.
  • Isolate the electrical supply and verify the fault is with the limiter rather than the thermostat or sensor circuit.
  • Check that the boiler has not tripped for a separate reason, such as poor circulation or a blocked heat exchanger.

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.