What it is
The Vokera ignition transformer TR6, part number 10026031, is an ignition unit used on Vokera gas boilers. It produces the high-voltage supply that creates the spark at the ignition electrode to light the burner. It is listed for the Vokera Compact 24 SE and Mynute 24 SE appliances.
Signs this part needs replacing
- Boiler fails to light and no spark is visible at the electrode
- Repeated lockouts during the ignition sequence
- Audible clicking from the transformer but no burner ignition
- Visible cracking, burning or damage to the transformer body or its leads
- Intermittent ignition or nuisance lockouts that clear on reset
Before you order
- Confirm the boiler model and GC number from the appliance data badge
- Check the existing transformer is marked with part number 10026031
- Inspect the ignition electrode and leads first, as a poor spark can originate elsewhere
- Isolate the electrical supply to the boiler before fitting
Compliance
| Alternative numbers | 1532711 |
|---|
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| VOKERA COMPACT 24 SE | 47-364-06 | 47-364-06 | — | — |
| VOKERA MYNUTE 24 SE | 41-094-73 | 41-094-73 | — | — |
| VOKERA VOKERA COMPACT 24 SE | — | — | — | |
| VOKERA VOKERA MYNUTE 24 SE | — | — | — |