Potterton DHW Diaphragm Flow Switch 10/18676
Diaphragm flow switch for the domestic hot water circuit on Potterton Combi 100, Ecotherm and Puma boilers.
At a glance
- Also known as DIAPHRAGM-FLOW-SWITCH-SPECIAL-TOTE, DIAPHRAGM---FLOW-SWITCH, 1120050
£110.40
£92.00 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The Potterton 10/18676 is a diaphragm flow switch used on the domestic hot water circuit of Potterton gas boilers. It detects water flow through the DHW side of the appliance and signals the boiler to fire for hot water demand. It is listed under boiler switches and supersedes the earlier code 451100.
Signs this part needs replacing
- No hot water demand registered — the boiler does not fire when a hot tap is opened.
- Hot water runs cold or intermittently while the central heating continues to work normally.
- The diaphragm is split, perished or stiff, so it no longer moves the switch actuator.
- The switch contacts fail to make or break cleanly, causing erratic firing on DHW.
- Water weeping or staining around the flow switch housing.
Before you order
- Confirm the boiler model and, where applicable, the control type fitted (SIT or Honeywell) against the manufacturer's parts list.
- Check the part number on the existing switch or its housing matches 10/18676.
- Inspect the diaphragm and switch assembly for mechanical damage before condemning the part.
- Isolate the water and power supplies before removal and refitting.
Compliance
| GC number | 289-724 |
|---|---|
| Barcode / EAN | 5039177574217 |
| Alternative numbers | DIAPHRAGM-FLOW-SWITCH-SPECIAL-TOTE, DIAPHRAGM---FLOW-SWITCH, 1120050 |
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| POTTERTON COMBI 100 | 47-393-04 | 47-393-04 | — | — |
| POTTERTON ECOTHERM EGC 12KW | — | — | — | |
| POTTERTON ECOTHERM EGC 18KW | — | — | — | |
| POTTERTON ECOTHERM EGC 24KW | — | — | — | |
| POTTERTON ECOTHERM EGCV 12KW | — | — | — | |
| POTTERTON ECOTHERM EGCV 18KW | — | — | — | |
| POTTERTON ECOTHERM EGCV 24KW | — | — | — | |
| POTTERTON POTTERTON COMBI 100 | — | — | — | |
| POTTERTON POTTERTON PUMA 100 E SIT / HONEYWELL CONTROLS | — | — | — | |
| POTTERTON POTTERTON PUMA 100 SIT / HONEYWELL CONTROLS | — | — | — |
Showing 10 of 16 compatible appliances.