Alpha
Alpha PCB Fuse 2.5 Amp 1.2379
2.5 amp printed circuit board fuse for Alpha CD series gas boilers, fitting board positions F2 and F3.
At a glance
- Also known as 1257817
£1.64
£1.37 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The Alpha 1.2379 is a 2.5 amp printed circuit board fuse used on Alpha CD series gas boilers. It protects the board circuit at positions F2 and F3. The fuse is a serviceable component that isolates the board from overcurrent faults.
Signs this part needs replacing
- The boiler fails to fire or does not respond to a call for heat
- No power, display or indicator lights on the control panel
- The fuse reads open circuit on a continuity test
- A replacement fuse blows again shortly after fitting, pointing to a fault elsewhere in the circuit
Before you order
- Confirm the fuse designation on your PCB is F2 or F3
- Check that the required rating is 2.5 amp
- Isolate the appliance from the electrical supply before removing the fuse
- Identify why the fuse failed before fitting a replacement, as fuses blow for a reason
Compliance
| Alternative numbers | 1257817 |
|---|
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| ALPHA ALPHA CD12S | — | — | — | |
| ALPHA ALPHA CD20S | — | — | — | |
| ALPHA CD12S | 41-532-16 | 41-532-16 | — | — |
| ALPHA CD12S (LPG) | 41-532-17 | 41-532-17 | — | — |
| ALPHA CD20S | 41-532-18 | 41-532-18 | — | — |
| ALPHA CD20S (LPG) | 41-532-19 | 41-532-19 | — | — |
| ALPHA CD25X | 47-532-39 | 47-532-39 | — | — |
| ALPHA CD25X (LPG) | 47-532-40 | 47-532-40 | — | — |
| ALPHA CD28S | 41-532-20 | 41-532-20 | — | — |
| ALPHA CD28S (LPG) | 41-532-21 | 41-532-21 | — | — |
Showing 10 of 12 compatible appliances.
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
ALPHA appliance manual — CD12S (GC 41-532-16), CD12S (LPG) (GC 41-532-17), CD20S (GC 41-532-18), CD20S (LPG) (GC 41-532-19), CD28S (GC 41-532-20), CD28S (LPG) (GC 41-532-21)
manualmanualALPHA appliance manual — CD25X (GC 47-532-39), CD25X (LPG) (GC 47-532-40), CD28X (GC 47-532-37), CD28X (LPG) (GC 47-532-38)
manualNo technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.