Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Trade account
Reznor Fan Motor 01 25636

Reznor

Reznor Fan Motor 01 25636

Reznor fan motor, part number 01 25636, for LCSA, UDSA, UESA, UPA and V3 warm air and room sealed heaters.

At a glance

  • Also known as 2530286
Manufacturer part no.
01 25636
Showing prices

£836.84

£697.37 ex. VAT · VAT at 20%

Available to order · 7 working days
Available to order · 7 working days
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.Call the technical teamSend a technical question

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Reznor 01 25636 is a fan motor for Reznor warm air unit heaters and room sealed heaters. It drives the fan assembly that moves air across the heat exchanger and into the heated space. The unit carries the motor reference PO F48T13A13.

Signs this part needs replacing

  • The fan does not turn when the heater calls for heat, or runs only after the shaft is helped by hand.
  • The motor overheats or the thermal protection trips repeatedly, cutting the fan out during a run cycle.
  • Grinding, rumbling or scraping noise from the fan area while the heater is operating.
  • Burning smell or visible scorching at the motor windings, terminals or capacitor connections.
  • The fan runs slowly and unevenly, reducing air output and causing the appliance to cycle on its limit thermostat.

Before you order

  • Confirm the appliance model and match it against the fit list above before ordering.
  • Read the motor reference from the existing motor and check it against PO F48T13A13.
  • Check the fan blade, capacitor and wiring for damage, since a failed capacitor or obstructed blade can mimic motor failure.
  • Isolate the electrical supply and follow the appliance manufacturer's instructions when removing and refitting the motor.

Not sure which part?

Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.