Vaillant
Vaillant Elbow 0020211097
Vaillant flue elbow 0020211097 for EcoTEC PLUS, Ecofit and Home series boilers, used to connect and route flue pipe sections.
At a glance
- Also known as 1388044
£9.67
£8.06 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The Vaillant 0020211097 is a flue elbow used within the flue system of Vaillant gas boilers. It connects sections of flue pipe and forms part of the route that carries combustion products away from the appliance. It is listed for use across a range of Vaillant Home, Ecofit and ecoTEC PLUS models.
Signs this part needs replacing
- Visible corrosion, cracking or distortion of the elbow
- Condensate weeping or staining at the elbow joint
- Flue joints that will not seal correctly
- Staining or a smell of combustion products around the flue route
- The elbow no longer sits correctly when the flue is reassembled
Before you order
- Confirm your boiler model and GC number against the fitment list above.
- Check the part number on the existing elbow or against the manufacturer's parts list for your appliance.
- Confirm the elbow is the correct item for your flue configuration before fitting.
Compliance
| Alternative numbers | 1388044 |
|---|
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| VAILLANT HOME COMBI 25 -A | 47-044-62 | 47-044-62 | — | — |
| VAILLANT HOME COMBI 30 -A | 47-044-63 | 47-044-63 | — | — |
| VAILLANT HOME COMBI 35 -A | 47-044-64 | 47-044-64 | — | — |
| VAILLANT HOME REGULAR 12 -A | 41-044-88 | 41-044-88 | — | — |
| VAILLANT HOME REGULAR 15 -A | 41-044-89 | 41-044-89 | — | — |
| VAILLANT HOME REGULAR 18 -A | 41-044-90 | 41-044-90 | — | — |
| VAILLANT HOME REGULAR 25 -A | 41-044-92 | 41-044-92 | — | — |
| VAILLANT HOME REGULAR 30 -A | 41-044-93 | 41-044-93 | — | — |
| VAILLANT HOME SYSTEM 12 -A | 41-044-94 | 41-044-94 | — | — |
| VAILLANT HOME SYSTEM 15 -A | 41-044-95 | 41-044-95 | — | — |
Showing 10 of 59 compatible appliances.
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
VAILLANT appliance manual — HOME COMBI 25 -A (GC 47-044-62), HOME COMBI 30 -A (GC 47-044-63), HOME COMBI 35 -A (GC 47-044-64)
manualmanualVAILLANT appliance manual — HOME REGULAR 12 -A (GC 41-044-88), HOME REGULAR 15 -A (GC 41-044-89), HOME REGULAR 18 -A (GC 41-044-90), HOME REGULAR 25 -A (GC 41-044-92), HOME REGULAR 30 -A (GC 41-044-93)
manualmanualVAILLANT appliance manual — HOME SYSTEM 12 -A (GC 41-044-94), HOME SYSTEM 15 -A (GC 41-044-95), HOME SYSTEM 18 -A (GC 41-044-96), HOME SYSTEM 25 -A (GC 41-044-97)
manualmanualVAILLANT appliance manual — VU 126/6-5 OV (GC 41-044-71), VU 156/6-5 OV (GC 41-044-72), VU 186/6-5 OV (GC 41-044-73), VU 246/6-5 OV (GC 41-044-74), VU 306/6-5 OV (GC 41-044-75), ecoTEC PLUS 412 VU 126/6-5 OV (2015) (GC 41-044-71), ecoTEC PLUS 415 VU 156/6-5 OV (2015) (GC 41-044-72), ecoTEC PLUS 418 VU 186/6-5 OV (2015) (GC 41-044-73), ecoTEC PLUS 424 VU 246/6-5 OV (2015) (GC 41-044-74), ecoTEC PLUS 430 VU 306/6-5 OV (2015) (GC 41-044-75)
manualmanualVAILLANT appliance manual — VU 126/6-5 OVZ (GC 41-694-13), VU 156/6-5 OVZ (GC 41-694-14), VU 186/6-5 OVZ (GC 41-694-15), VU 246/6-5 OVZ (GC 41-694-16), VU 306/6-5 OVZ (GC 41-694-17), VU 356/6-5 OVZ (GC 41-044-76), ecoTEC PLUS 412 VU 126/6-5 OVZ (2016) (GC 41-694-13), ecoTEC PLUS 415 VU 156/6-5 OVZ (2016) (GC 41-694-14), ecoTEC PLUS 418 VU 186/6-5 OVZ (2016) (GC 41-694-15), ecoTEC PLUS 424 VU 246/6-5 OVZ (2016) (GC 41-694-16), ecoTEC PLUS 430 VU 306/6-5 OVZ (2016) (GC 41-694-17), ecoTEC PLUS 435 VU 356/6-5 OVZ (2016) (GC 41-044-76)
manualmanualVAILLANT appliance manual — ecoFIT PURE 412 - VU 126/6-3 OV (2016) (GC 41-694-08), ecoFIT PURE 415 - VU 156/6-3 OV (2016) (GC 41-694-09), ecoFIT PURE 418 - VU 186/6-3 OV (2016) (GC 41-694-10), ecoFIT PURE 425 - VU 256/6-3 OV (2016) (GC 41-694-11), ecoFIT PURE 430 - VU 306/6-3 OV (2016) (GC 41-694-12), ecoFIT PURE 435 - VU 356/6-3 OV (2016) (GC 41-694-19)
manualmanualVAILLANT appliance manual — ecoFIT PURE 612 - VU 126/6-3 (2016) (GC 41-694-03), ecoFIT PURE 615 - VU 156/6-3 (2016) (GC 41-694-04), ecoFIT PURE 618 - VU 186/6-3 (2016) (GC 41-694-05), ecoFIT PURE 625 - VU 256/6-3 (2016) (GC 41-694-06), ecoFIT PURE 630 - VU 306/6-3 (2016) (GC 41-694-07)
manualmanualVAILLANT appliance manual — ecoFIT PURE 825 - VUW 256/6-3 (2016) (GC 47-044-68), ecoFIT PURE 830 - VUW 306/6-3 (2016) (GC 47-044-74), ecoFIT PURE 835 - VUW 356/6-3 (2016) (GC 47-044-70)
manualmanualVAILLANT appliance manual — ecoFIT SUSTAIN 415 - VU 156/6-3 OV (2018) (GC 41-694-33), ecoFIT SUSTAIN 418 - VU 186/6-3 OV (2018) (GC 41-694-34), ecoFIT SUSTAIN 430 - VU 306/6-3 OV (2018) (GC 41-694-35)
manualmanualVAILLANT appliance manual — ecoFIT SUSTAIN 615 - VU 156/6-3 (2018) (GC 41-694-30), ecoFIT SUSTAIN 618 - VU 186/6-3 (2018) (GC 41-694-31), ecoFIT SUSTAIN 630 - VU 306/6-3 (2018) (GC 41-694-32)
manualmanualVAILLANT appliance manual — ecoFIT SUSTAIN 825 - VUW 256/6-3 (2016) (GC 47-044-71), ecoFIT SUSTAIN 830 - VUW 306/6-3 (2016) (GC 47-044-72), ecoFIT SUSTAIN 835 - VUW 356/6-3 (2016) (GC 47-044-73)
manualNo technical questions yet for this part.
Not sure which part?
Search by part number, product name or brand — our technical team confirms fitment before anything is dispatched.