Checking hours…Mon–Fri 7:30am–5pm · Sat 9am–12pm01302 279234Find parts by applianceTrade account
Ideal Condensate Hose Internal 176478

Ideal

Ideal Condensate Hose Internal 176478

Ideal internal condensate hose, part 176478, for Atlantic Combi and Classic 2 boilers and other Ideal models. Carries condensate away from the heat exchanger.

At a glance

  • Part type: Condensate assembly (internal condensate hose)
  • Also known as 1782100
Manufacturer part no.
176478
Showing prices

£14.41

£12.01 ex. VAT · VAT at 20%

Available to order · 3 working days (HRP Trade)
Available to order · 3 working days (HRP Trade)
Not certain it's the right part? The technical team verifies fitment before dispatch — no charge, and it stops a second trip.

Same-day dispatch

Ordered by 4pm Mon–Fri, 10:30am Sat.

30-day returns

Unused, in original packaging.

What it is

The Ideal internal condensate hose is the flexible pipe that carries acidic condensate water from the boiler's condensing heat exchanger or condensate trap down to the external drainage point. It is manufactured by Ideal for use inside their own appliances, so the bore, wall thickness and end fittings match the trap and sump connections on the boiler it was designed for. The hose sits within the casing and is exposed to warm, mildly acidic condensate throughout the heating season, which is why it eventually hardens, splits or blocks.

Signs this part needs replacing

  • Water pooling inside the boiler casing or dripping from the bottom of the appliance
  • Visible cracking, hardening or perishing on the hose wall, particularly at the bend or at the trap spigot
  • Condensate backing up in the trap, causing gurgling, intermittent lockout or a boiler that will not fire
  • White, chalky scale deposits or a sludgy residue inside the bore restricting flow
  • A damp or stained patch on the wall or floor beneath the boiler where condensate has escaped

Before you order

  • Confirm the appliance model and GC number against the compatibility list, as the same boiler family can use different condensate arrangements across build years
  • Check the existing hose routing and end connections before removal so the replacement can be refitted the same way
  • Note the alternative part number 1782100 when cross-referencing older stock or documentation
  • Isolate the appliance and allow the condensate trap to drain before dismantling any part of the condensate route

Not sure which part?

Tell the parts assistant what it's going into — the appliance make and model, or the GC number off the data badge — and it will check this part is on the fit list.