Vaillant
Vaillant Round Outlet Fan R2/R3 VAILLANT0020020008
Vaillant R2/R3 round outlet fan (0020020008), a combustion and exhaust component for Vaillant gas boilers, supplied singly.
At a glance
- Also known as 1387506, VAILLANT0020020008
£199.19
£165.99 ex. VAT · VAT at 20%
Same-day dispatch
Ordered by 4pm Mon–Fri, 10:30am Sat.
30-day returns
Unused, in original packaging.
What it is
The Vaillant R2/R3 round outlet fan is a combustion and exhaust component used on Vaillant gas boilers. It sits in the flue gas path and moves products of combustion through the heat exchanger and out to atmosphere, while drawing the air the burner needs. It is supplied by Vaillant under part number 0020020008 as a single unit.
Signs this part needs replacing
- The boiler locks out or fails to fire, with a fan or flue-related fault code shown on the display.
- The fan becomes noisy in use, with rumbling, scraping or bearing whine audible from the casing.
- The fan runs intermittently or not at all when the boiler is called for heat, so the sequence stalls before ignition.
- Soot deposits, discoloured flue readings or repeated flame-failure faults point to reduced combustion air flow.
- Visible damage to the fan housing, outlet spigot or impeller on inspection.
Before you order
- Check the boiler's data badge and serial number, then match the part number 0020020008 against the appliance documentation.
- Confirm the existing fan carries the same R2/R3 round outlet pattern, as the housing and outlet shape vary between fan assemblies.
- Inspect the fan mounting gasket or seal and replace it if it is compressed, torn or hardened, so the flue path stays airtight.
Mechanical
| Part type | R2/R3 Round Outlet Fan |
|---|
Compliance
| Manufacturer part number (MPN) | 0020020008 |
|---|---|
| Commodity code | 8414 59 00 00 |
| GPC classification | Household Boilers/Furnaces/Tank Water Heaters Replacement Parts/Accessories |
| Alternative numbers | VAILLANT0020020008, 1387506 |
| Make | Model / assembly | Reference | Years | Fitment |
|---|---|---|---|---|
| VAILLANT THERMOcompact 615E VU 152/2-5 R3 (2004-2006) | 41-044-23 | 41-044-23 | — | — |
| VAILLANT THERMOcompact 620E VU 202/2-5 R2 (2003-2004) | 41-044-24 | 41-044-24 | — | — |
| VAILLANT THERMOcompact 620E VU 202/2-5 R3 (2004-2006) | 41-044-24 | 41-044-24 | — | — |
| VAILLANT THERMOcompact 624E VU 242/2-5 R2 (2003-2004) | 41-044-25 | 41-044-25 | — | — |
| VAILLANT THERMOcompact 624E VU 242/2-5 R3 (2004-2006) | 41-044-25 | 41-044-25 | — | — |
| VAILLANT THERMOcompact 628E VU 282/2-5 R2 (2003-2004) | 41-044-26 | 41-044-26 | — | — |
| VAILLANT THERMOcompact 628E VU 282/2-5 R3 (2004-2006) | 41-044-26 | 41-044-26 | — | — |
| VAILLANT THERMOcompact 637E VU 362/2-5 R3 (2004-2006) | 41-044-32 | 41-044-32 | — | — |
| VAILLANT TURBOmax Plus 824E VUW 242/2-5 (2001-2002) | 47-044-04 | 47-044-04 | — | — |
| VAILLANT TURBOmax Plus 824E VUW 242/2-5 R2 (2003-2004) | 47-044-04 | 47-044-04 | — | — |
Showing 10 of 50 compatible appliances.
Documents & drawings
Everything we hold for this part. Where a document exists but we don't hold it, the technical team will source it from the manufacturer — usually the same working day.
VAILLANT appliance manual — THERMOcompact 615E VU 152/2-5 R3 (2004-2006) (GC 41-044-23), THERMOcompact 620E VU 202/2-5 R2 (2003-2004) (GC 41-044-24), THERMOcompact 620E VU 202/2-5 R3 (2004-2006) (GC 41-044-24), THERMOcompact 624E VU 242/2-5 R2 (2003-2004) (GC 41-044-25), THERMOcompact 624E VU 242/2-5 R3 (2004-2006) (GC 41-044-25), THERMOcompact 628E VU 282/2-5 R2 (2003-2004) (GC 41-044-26), THERMOcompact 628E VU 282/2-5 R3 (2004-2006) (GC 41-044-26), THERMOcompact 637E VU 362/2-5 R3 (2004-2006) (GC 41-044-32), TURBOmax Plus 824E VUW 242/2-5 (2001-2002) (GC 47-044-04), TURBOmax Plus 824E VUW 242/2-5 R2 (2003-2004) (GC 47-044-04), TURBOmax Plus 824E VUW 242/2-5 R3 (2004-2004) (GC 47-044-04), TURBOmax Plus 828E VUW 282/2-5 R2 (2003-2004) (GC 47-044-09), TURBOmax Plus 828E VUW 282/2-5 R3 (2004-2004) (GC 47-044-09), TURBOmax Plus 837E VUW 362/2-5 R3 (2004-2004) (GC 47-044-28), VU 152/2-5 R3 (GC 41-044-23), VU 202/2-5 R2 (GC 41-044-24), VU 202/2-5 R3 (GC 41-044-24), VU 242/2-5 R2 (GC 41-044-25), VU 242/2-5 R3 (GC 41-044-25), VU 282/2-5 R2 (GC 41-044-26), VU 282/2-5 R3 (GC 41-044-26), VU 362/2-5 R3 (GC 41-044-32), VUW 242/2-5 R2 (GC 47-044-04), VUW 242/2-5 R3 (GC 47-044-04), VUW 282/2-5 R2 (GC 47-044-09), VUW 282/2-5 R3 (GC 47-044-09), VUW 362/2-5 R3 (GC 47-044-28)
manualmanualVAILLANT appliance manual — TURBOmax Pro 24E VUW 242/2-3 R2 (2003-2004) (GC 47-044-10), TURBOmax Pro 24E VUW 242/2-3 R3 (2004-2004) (GC 47-044-10), TURBOmax Pro 28E VUW 282/2-3 R2 (2003-2004) (GC 47-044-11), TURBOmax Pro 28E VUW 282/2-3 R3 (2004-2004) (GC 47-044-11), VUW 242/2-3 R2 (GC 47-044-10), VUW 242/2-3 R3 (GC 47-044-10), VUW 282/2-3 R2 (GC 47-044-11), VUW 282/2-3 R3 (GC 47-044-11)
manualNo technical questions yet for this part.